WindPRO version 2.9.269 Nov 2013
Project:
Printed/Page
Ulvemosen
24-01-2014 18:57 / 1
Licensed user:
European Wind Farms Denmark a/s
Diplomvej 377
DK-2800 Kgs. Lyngby
+45 88 70 82 10
Calculated:
24-01-2014 18:52/2.9.269
DECIBEL - Main Result
Calculation:
10x Vestas V117-3.3 MW+ all existing WTGs - værditab
Noise calculation model:
Danish 2011
The calculation is based on the "Bekendtgørelse nr. 1284 af 15. december 2011" from the Danish
Environmental Agency.
The noise impact from WTGs are not allowed to exceed the following limits: (Wind speeds in 10 m
height)
1) At outdoor areas maximum 15 m from neighbor settlements in the open land.
a) 44 db(A) at wind speed 8 m/s.
b) 42 db(A) at wind speed 6 m/s.
2) At outdoor areas in residential or recreational areas.
a) 39 db(A) at wind speed 8 m/s in residential areas.
b) 37 db(A) at wind speed 6 m/s in residential areas.
The low frequency noise impact from WTGs are not allowed to exceed 20 dB indoor at wind
speeds 8 and 6 m/s
The limits are not to be taken into acount for houses belonging to WTG owner
WTGs
UTM (north)-ETRS89 Zone: 32
East
North
Z Row data/Description
[m]
23,3
25,4
27,4
28,8
29,0
29,9
30,0
28,0
25,3
20,0
20,0
20,7
23,0
23,4
25,8
26,1
22,2
23,1
20,7
21,6
20,0
20,0
20,0
20,0
20,0
20,0
20,0
20,0
20,0
20,3
30,0
WTG type
Valid Manufact.
Type-generator
New WTG
Noise sensitive area
Noise data
Power, Rotor
Hub
Creator Name
rated diameter height
[kW]
3.300
3.300
3.300
3.300
3.300
3.300
3.300
3.300
3.300
3.300
660
660
660
660
660
660
750
750
750
750
900
900
900
900
900
900
900
900
900
600
11
[m]
117,0
117,0
117,0
117,0
117,0
117,0
117,0
117,0
117,0
117,0
47,0
47,0
47,0
47,0
47,0
47,0
48,2
48,2
48,2
48,2
52,0
52,0
52,0
52,0
52,0
52,0
52,0
52,0
52,0
44,0
13,0
[m]
91,5
91,5
91,5
91,5
91,5
91,5
91,5
91,5
91,5
91,5
45,0
45,0
45,0
45,0
45,0
45,0
45,0
45,0
45,0
45,0
44,0
44,0
44,0
44,0
44,0
44,0
44,0
44,0
44,0
45,0
18,0
USER
USER
USER
USER
USER
USER
USER
USER
USER
USER
EMD
EMD
EMD
EMD
EMD
EMD
USER
USER
USER
USER
EMD
USER
USER
USER
USER
USER
USER
USER
USER
USER
EMD
Scale 1:125.000
Existing WTG
f) From other hub height
b) Data from Danish Environmental Agency
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
474.321
474.762
475.243
475.709
476.185
476.661
477.118
477.533
477.936
478.320
476.954
476.859
477.243
477.148
477.500
477.404
476.322
476.094
476.202
475.973
477.888
477.891
477.890
477.448
477.449
477.450
477.674
477.676
477.677
473.893
482.375
6.161.556
6.161.414
6.161.338
6.161.322
6.161.358
6.161.458
6.161.626
6.161.850
6.162.083
6.162.361
6.159.254
6.159.034
6.159.128
6.158.908
6.159.016
6.158.796
6.159.530
6.159.629
6.159.321
6.159.421
6.164.329
6.164.564
6.164.800
6.162.686
6.162.911
6.163.135
6.162.686
6.162.910
6.163.134
6.161.939
6.161.352
VESTAS V117-3.3 MW 3300 11... Yes
VESTAS V117-3.3 MW 3300 11... Yes
VESTAS V117-3.3 MW 3300 11... Yes
VESTAS V117-3.3 MW 3300 11... Yes
VESTAS V117-3.3 MW 3300 11... Yes
VESTAS V117-3.3 MW 3300 11... Yes
VESTAS V117-3.3 MW 3300 11... Yes
VESTAS V117-3.3 MW 3300 11... Yes
VESTAS V117-3.3 MW 3300 11... Yes
VESTAS V117-3.3 MW 3300 11... Yes
570715000000034787: 660 kW ... No
570715000000034794: 660 kW ... No
570715000000034800: 660 kW ... No
570715000000034817: 660 kW ... No
570715000000034824: 660 kW ... No
570715000000034831: 660 kW ... No
570715000000035036: 750 kW ... Yes
570715000000035562: 750 kW ... Yes
570715000000035579: 750 kW ... Yes
570715000000035586: 750 kW ... Yes
570715000000063619: 900 kW ... Yes
570715000000063626: 900 kW ... Yes
570715000000063633: 900 kW ... Yes
570715000000063657: 900 kW ... Yes
570715000000063664: 900 kW ... Yes
570715000000063671: 900 kW ... Yes
570715000000063688: 900 kW ... Yes
570715000000063695: 900 kW ... Yes
570715000000063701: 900 kW ... Yes
570715000000034619: 600 kW ... No
570715000000034572: 11 kW ... Yes
VESTAS
VESTAS
VESTAS
VESTAS
VESTAS
VESTAS
VESTAS
VESTAS
VESTAS
VESTAS
VESTAS
VESTAS
VESTAS
VESTAS
VESTAS
VESTAS
NEG MICON
NEG MICON
NEG MICON
NEG MICON
NEG MICON
NEG MICON
NEG MICON
NEG MICON
NEG MICON
NEG MICON
NEG MICON
NEG MICON
NEG MICON
VESTAS
GAIA WIND
V117-3.3 MW-3.300
V117-3.3 MW-3.300
V117-3.3 MW-3.300
V117-3.3 MW-3.300
V117-3.3 MW-3.300
V117-3.3 MW-3.300
V117-3.3 MW-3.300
V117-3.3 MW-3.300
V117-3.3 MW-3.300
V117-3.3 MW-3.300
V47-660/200
V47-660/200
V47-660/200
V47-660/200
V47-660/200
V47-660/200
NM48/750-750/200
NM48/750-750/200
NM48/750-750/200
NM48/750-750/200
NM52/900-900/200
NM52/900-900/200
NM52/900-900/200
NM52/900-900/200
NM52/900-900/200
NM52/900-900/200
NM52/900-900/200
NM52/900-900/200
NM52/900-900/200
V44-600
GAIA 11 KW-11
Mode 2 - 104,5 dB - 2013-12-04
Mode 0 - 107 dB - 2013-12-04
Mode 0 - 107 dB - 2013-12-04
Mode 0 - 107 dB - 2013-12-04
Mode 0 - 107 dB - 2013-12-04
Mode 5 - 104 dB - 2013-12-04
Mode 5 - 104 dB - 2013-12-04
Mode 5 - 104 dB - 2013-12-04
Mode 0 - 107 dB - 2013-12-04
Mode 0 - 107 dB - 2013-12-04
Level 0 - measurement - - 1997-06
Level 0 - measurement - - 1997-06
Level 0 - measurement - - 1997-06
Level 0 - measurement - - 1997-06
Level 0 - measurement - - 1997-06
Level 0 - measurement - - 1997-06
Måling, Ribe Amt, Roust-Høje, mølle 3
Måling, Ribe Amt, Roust-Høje, mølle 1
Måling, Ribe Amt, Roust-Høje, mølle 4
Måling, Ribe Amt, Roust-Høje, mølle 2
8m/s 44m Man. 01-2002
Level 0 - measurement - - 2000/12
Level 0 - measurement - - 2000/12
Level 0 - measurement - - 2000/12
Level 0 - measurement - - 2000/12
Level 0 - measurement - - 2000/12
Level 0 - measurement - - 2000/12
Level 0 - measurement - - 2000/12
Level 0 - measurement - - 2000/12
Level 0 - measurement - - 1995-08
8m/s Man. 24-01-96
First LwaRef
wind
speed
[m/s] [dB(A)]
6,0
103,8
6,0
105,1
6,0
105,1
6,0
105,1
6,0
105,1
6,0
102,0
6,0
102,0
6,0
102,0
6,0
105,1
6,0
105,1
6,0
99,1
6,0
99,1
6,0
99,1
6,0
99,1
6,0
99,1
6,0
99,1
6,0
96,6
6,0
96,6
6,0
96,6
6,0
96,6
6,0
101,0 b
6,0
98,7
6,0
98,7
6,0
98,7
6,0
98,7
6,0
98,7
6,0
98,7
6,0
98,7
6,0
98,7
6,0
99,1 f
6,0
93,2 b
Last LwaRef
Pure
wind
tones
speed
[m/s] [dB(A)]
8,0
104,5
No
8,0
107,0
No
8,0
107,0
No
8,0
107,0
No
8,0
107,0
No
8,0
104,0
No
8,0
104,0
No
8,0
104,0
No
8,0
107,0
No
8,0
107,0
No
8,0
99,8
No
8,0
99,8
No
8,0
99,8
No
8,0
99,8
No
8,0
99,8
No
8,0
99,8
No
8,0
99,4
No
8,0
99,0
No
8,0
99,8
No
8,0
101,5
No
8,0
103,9 b
No
8,0
100,3
No
8,0
100,3
No
8,0
100,3
No
8,0
100,3
No
8,0
100,3
No
8,0
100,3
No
8,0
100,3
No
8,0
100,3
No
8,0
99,5 f
No
8,0
95,1 b
No
Calculation Results
Sound Level
Noise sensitive area
No.
Name
UTM (north)-ETRS89 Zone: 32
Demands Sound Level
Demands fulfilled ?
East
North
Z Imission Wind
Noise
From Distance to
Noise
height speed
WTGs
noise
demand
[m]
[m]
[m/s]
[dB(A)] [dB(A)]
[m]
A Møgelbjergvej 16, Næsbjerg 6800 Varde 476.797 6.162.118 25,7
1,5
6,0
42,0 41,9
8
Yes
A
8,0
44,0 43,7
40
Yes
To be continued on next page...
WindPRO is developed by EMD International A/S, Niels Jernesvej 10, DK-9220 Aalborg Ø, Tel. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: [email protected]